Case-specific: Membranes LE-4040 5000 GPD With recycle and 75% recovery

Membrane system
Feed Flow to Stage 1 7.63 gpm
Raw Water Flow to System 4.63 gpm
Feed Pressure 105.55 psig
Flow Factor 0.85
Chem. Dose (100% H2SO4) 0.00
Total Active Area 282.00 ft²
Water Classification: Well Water SDI < 3
Pass 1 Permeate Flow 3.47 gpm
Pass 1 Recovery 75.00 %
Feed Temperature 25.0 C
Feed TDS 550.01 mg/l
Number of Elements 3
Average Pass 1 Flux 17.72 gfd
Osmotic Pressure:
Feed 6.57 psig
Concentrate 25.17 psig
Average 15.87 psig
Average NDP 73.48 psig
Power 0.44 kW
Specific Energy 2.10 kWh/kgal