Pre-Treatment Lockout Sends a signal to the RO system when a pre-treatment lockout condition occurs Tank Level Input Sends a signal to the RO system when a tank full or tank low condition occurs S150 Expander Board I/O expander board allows for 2 additional relay outputs and 1 additional switch input S150 Dual TDS Board ... Read More »
Tag Archives: Osmose inverse
Membrane system feed flush
June 16, 2020
FLUSHING RO SYSTEM During flush, pump is off. Feed water is around 60 psi, permeate divert solenoid valve is closed, but diverted permeate pressure that is around 30 psi (less than inlet pressure) cannot enter in feed flush because inlet water pressure is too high. So permeate in note recycled. During production, when diverted permeate ... Read More »
Low Energy Membranes
July 29, 2016
Very good article of Bill Loyd in Watertechonline Taking advantage of low pressure membranes in commercial systems Note that AXEON Water Technologies has developped an extra low Energy RO membranes that are supposed to operate at pressure of 80 psi. I haven’t tried them yet, but this is an interesting innovation. Info here. These types ... Read More »
Performances of some Filmtec membranes
May 14, 2016
NOTES FROM DIFFERENT SOURCES AND PERSONAL Performance of some FILMTEC membranes SW30HR BW30 XLE NF270 Feed pressure (psi) 370 150 70 50 Feed pressure (bar) 25 10 5 3.5 Rejection (%) Sodium chloride NaCl 99.7 99.4 98.6 80 Calcium chloride CaCl2 99.8 99.4 98.8 50 Magnesium sulfate MgSO4 99.9 99.7 99.2 99.3 At 18 ... Read More »
Membrane filtration overview
March 23, 2016
Sorry, this entry is only available in Français. Read More »
(Français) Intégrité des membranes spiralées
April 11, 2014
Sorry, this entry is only available in Français. Read More »
Cleaning water treatment membrane systems
October 6, 2013
Sorry, this entry is only available in Français. Read More »
Water treatment membrane systems validation
October 6, 2013
In Quebec, membrane treatment technology applied to water treatment needs a ministry approval before implantation. The system must undergo to a specific procedure enacted by the ministry of environment and managed buy Quebec office of normalization (BNQ). Read More »