Pre-Treatment Lockout
Sends a signal to the RO system when a pre-treatment lockout condition occurs
Tank Level Input
Sends a signal to the RO system when a tank full or tank low condition occurs
S150 Expander Board
I/O expander board allows for 2 additional relay outputs and 1 additional switch input
S150 Dual TDS Board and Sensor***
Allows for the monitoring of the feed water TDS
S200 Rotrol II Controller Feed TDS Sensor
Allows for monitoring of the feed water TDS
Variable Frequency Drive*
Allows for adjustment of the motor for specific amp draw and pressure
S200 pH Monitoring
Allows for monitoring of pH in the RO systems product water
S200 ORP Monitoring
Allows for monitoring of ORP in the RO systems feed water
Chemical Pump Outlet
Provides an integrated power source with the RO system for connection of a chemical feed pump
Pump Pressure Relief Valve
Helps in protecting the RO system at a pre-determined setting by relieving the pressure when pressures exceed too high
Blending Valve
Allows for a mixture of feed water into the final reverse osmosis product water to achieve a fine-tuned product TDS
Controller Permeate TDS Monitoring
Allows for the monitoring of the reverse osmosis product water TDS
Controller Feed TDS Monitoring
Allows for the monitoring of the feed water TDS
Victaulic® Style Fittings
316 stainless steel coupling for high pressure and corrosion resistant
Permeate Divert Valve
Diverts the product water to the drain (waste water side) if the TDS reaches a desired set-point on the computer controller
High Pressure Tank Switch
Automatically turns off the ro system at a pre-determined storage tank pressure
Motor Actuated Feed Valve
Prevents water flow through the system during shutdown
Concentrate Recycle Flow Meter
Monitors the waste water flow rate
Concentrate Recycle valve
Needle valve controls the waste water being recycled back through the RO system
Stainless Steel Concentrate Globe Valve
Allows for control of the waste water
Feed Flush
Low flow feed water flush to reduce concentrated water on the RO membrane element
Permeate Sample Ports
Allows for evaluation of individual membrane performance and aids in system troubleshooting and maintenance
Vertical Multi-Stage Stainless Steel Booster Pump
High pressure pump provides steady, quiet, vibration-free operation and is designed for continuous operation. High resistance to corrosion and abrasion
Feed Low Pressure Switch
Protects the RO pump from damage and cavitation when a low pressure condition occurs
High Pressure Switch
Protects the RO system when a high pressure condition occurs shutting down the system
Auto Feed Shut-Off
Motorized feed valve automatically closes when an alarm condition occurs
Clean-In-Place (CIP) Ports
Allows for cleaning of the RO systems membrane
Feed Solenoid Valve
Solenoid valve features a high flow and low friction loss
High flow, low friction loss design that has a pressure range of 10 to 125 psi, offers a manual override handle for valve actuation
Victaulic® Style Fittings
316 stainless steel coupling for high pressure and corrosion resistant
Caster Wheels
Allows for mobility of the ro system
Wooden Crate
Added protection around the system during shipment, covers all six sides
Three Panel Switches
Three panel switches which consist of auxiliary output enable or disable, RO pump and system power
CONTROLLERS
S200 Controller
• LCD Backlit Display
• Pre-Treatment Lockout
• Tank Level Input
• LED Low Pressure Monitoring and Alarm
• Hour Meter
• Dual TDS Monitoring
• Feed Flush
• Digital Flow Meters x 3 S150 Controller
• LCD Backlit Display
• Pre-Treatment Lockout
• Tank Level Input
• Low Pressure Monitoring and Alarm
• Hour Meter
• Feed Flush C22 Controller
• LED Display
• Pre-Treatment Lockout
• Tank Level Input
• Low Pressure Monitoring and Alarm
• TDS Monitoring
• Feed Flush Minitrol Controller
• Multi Color LED Indicator Status Light
• Pre-Treatment Lockout
• Tank Level Input
• Low Pressure Monitoring and Alarm
S150 Computer Controller and S200 Computer Controller
Allows for pre-treat lockout functionality, tank level input, permeate TDS monitoring, low pressure monitoring, feed flush, electronic flush bypass and features a convenient LED display, alarm functionality and other monitoring options
S-150 Microprocessor Controller
Features 6 switch inputs, 5 analog inputs, 6 relay outputs and 2 TDS conductivity inputs. Also features a four line by 20 character LCD display that provides sensor readings, hours of operation, temperature, alarms and operating status of the RO system
Minitrol computer controller
Provides a 20 amp output relay for the RO pump and inlet solenoid, and monitors switch inputs from a pressure switch. These inputs allow the RO unit to either run or shutdown as necessary for proper operation. Tank level and pre-treatment inputs control the RO system
Minitrol IF Computer Controller with Feed Flush
Provides a 20 amp output relay for the RO pump and inlet solenoid, and monitors switch
inputs from a pressure switch. These inputs allow the RO unit to either run or shutdown
as necessary for proper operation. Tank level and pre-treatment inputs control the RO system along with an optional flush cycle
Manual On and Off Control Switch
Provides start and stop of the RO system